Boiler Control Training Seminar
April 14-15, 2025 | 10 Marianne Drive York, Pennsylvania 17406

Reduce costs in your boiler plant while making it cleaner, safer, and more reliable.
By automating control of their boiler plant with Autoflame touchscreen controllers and servomotors, customers can recoup their investment in as little as 1-2 years just in fuel savings. Add in the benefits of emission reduction, reliability, and safety, and the upgrades become even more attractive. Limpsfield Burners are guaranteed to produce 3% or less O2 when firing gas while producing negligible CO.
We invite you to attend the Autoflame/Limpsfield Product Training Seminar being held by CSI Services. This 2-day seminar will cover the Autoflame Combustion Management System and Limpsfield burners, and will involve in-depth technical presentations and hands-on training.
If you already use Autoflame or Limpsfield equipment, or want to learn about their benefits, this is a great opportunity to learn more about:
- Mk8 MM and Mini Mk8 MM Control Overview
- Peripheral Parts Installation and Setup
- System configuration
- Lead-Lag control/sequencing (IBS) Overview
- Mk8 MM Expansion Features overview
- Troubleshooting
- Mk8 MM Expansion Features overview
- Troubleshooting
- Mk8 EGA Evo
- Mk8 DTI
- Burner/Boiler Efficiency and Savings
- Burner Start-Up
- Electrical Installation Guide
- System configuration
- Commissioning
Schedule – Day 1
- Introduction to Autoflame and Limpsfield
- Controller Overview
- Mk8 MM and Mini Mk8 MM
- Peripheral Parts Installation and Setup
- Servomotors
- Gas, air, and oil pressure sensors
- Load detectors
- Control valves and water valves
- Water Level Control probes
- Burner Start-Up
- The start-up sequence and burner terminals
- Gas and air pressure monitoring
- Electrical Installation Guide
- Wiring recommendations
- Cable specification
- VFD Installations
- System configuration
- Online changes
- Time, date, languag
- Runtimes scheduling
- Boiler room display
- Post-commissioning
- Single point change capabilities
- Golden Start position for optimum light off
- FGR start positions
- Fuel Flow Metering
- Guided lesson on demo rigs
Schedule – Day 2
- Burner/Boiler Efficiency and Savings (Limpsfield)
- Heat transfer and excess air
- Cycling
- Turndown
- Metering systems
- Adjustments
- PID Control
- Options and Parameter
- Operation and tips
- Troubleshooting
- Lockouts, Errors, Alarms, Warnings, First Outs
- System Log
- Diagnostics
- Lead-Lag control/sequencing (IBS)
- Options and Parameters
- Optimizing performance
- Mk8 MM Expansion Features
- Water level control and analogue water level
- Top blowdown and Bottom blowdown
- Heat Flow and utilisation of spare temperature inputs
- First Out Annunciation
- Direct Modbus
- Draught Control
- Fully Metered Combustion Control
- Fuel Change On the Fly
- Setpoint Schedule
- Mini Mk9 MM
- Autoflame Flame Safeguards
- Worksheet exercise
- Mk8 EGA Evo
- 3 Parameter trim
- Set up and configuration
- Servicing
- Mk8 DTI presentation/hands-on
- Operation and settings
- I/O module
- DTI Rules System
- 4G modem
- Download Manager and DTI Manager