100 BHP Mobile Boiler Room
Burnham Commercial 3P-100-50-LF
Introducing the 100 BHP Mobile Boiler Room by Burnham Commercial, a versatile powerhouse in a 40-foot container. This mobile boiler delivers 3,450 lbs. of steam per hour, offering the flexibility of natural gas or No. 2 Oil. Achieving low NOx emissions on natural gas, it’s compliant with environmental standards. Fully equipped with a dual fuel burner, UL Package Certified safety, and auxiliary equipment, it’s the efficient and eco-friendly solution you need. Simple connections and power requirements make it a turnkey solution for your steam needs.
100 BHP Mobile Boiler Room
One (1) 100 horsepower containerized mobile boiler room complete with one 3P-100 Burnham Commercial Low NOx steam boiler, combination natural gas or N0. 2 Oil fired, design pressure 150 psi, capable of producing 3,450 lbs. of steam per hour. NOx emissions on Natural Gas will be sub 30 ppm at <3% O2 from 25% to 100% MCR. System is in a 40-Foot Container on chassis.
The boiler comes complete with gas train, oil train, No. 2 fuel oil pump, second low water cut-off, pressure controls, flame safeguard control, relief valves, feedwater valves, blowdown valves, blowdown controller, blowdown separator and a fully modulating Limpsfield LP2/1465 dual fuel burner with Auto Flame controls. Boiler/Burner/Controls are UL Package Certified with CSD-1.
This Rental System Also Includes:
- One (1) Feedwater system – Shipco
- Two (2) Primary feedwater pumps – Gould with VFD Control’s
- One (1) Chemical feed system with pump, day tank, mixer, makeup meter and controls
- Twin canister makeup water softener with brine tank and controls
- One (1) surface blowdown controller with sensor and motorized ball valve
- One Siemens Modulating feedwater valve and with controller
- One Blowdown Flash tank
- Electrical switch gear
- One (1) main steam stop valve with DFT to supply manifold
- One (1) operator’s manual
Connection Sizes:
- Main steam outlet – 4”, 150# flanged
- Natural gas connection – 1.25″, NPT
- Maximum inlet pressure to gas regulator – 10 PSIG
- Oil is pre-piped, fuel tank not supplied
- Feedwater – 1” MPT
- Blowdown Separator Drain – 4”; must be full flow
- System Drain 2”, must be full flow
Fuel Requirements:
- Natural gas consumption 4,184 SCFH
- No, 2 Fuel Oil – 105 GPH
Voltage and Amperage Requirements:
- 480 volts, 100-amp service, 3-phase
- 115 Volt, Single Phase Transform included